Here is a recent problem which would appear to be quite common. The end of the connector on a lightning cable was stuck inside the charging / accessory port. This worryingly appears to be a frequent occurrence resulting from the use of cheap, unbranded cables where the tip of the connector can break off, forming a staple-shaped piece, jamming itself into the iPhone or iPad. The result is that it is impossible to charge the device, unless the broken connector lead is retained, as it is the only one now small enough to fit into the accessory port.
This problem can render the expensive phone or tablet useless. For older out-of-warranty products it is potentially not worth a repair investigation and even with newer devices this may be classified as ‘accidental damage’, requiring extended insurance cover to avoid a significant resolution cost.
Happily, it may be possible to address the problem using the following simple technique:
Use a ultra-small, precision screwdriver. It needs to be small enough to easily fit inside the accessory port and be able to be levered across it’s width, whilst being sturdy enough not to bend or break.
Insert into the device’s accessory port, and position sideways across the width of the opening, such that the end of the tool is pressing on the inside of the port about half-way in / up.
Then, with an outwards ‘levering’ action, pull the broken connector piece out of the port.
If fortunate, this will remove the obstruction and return the device to an operational state. Naturally, success is not certain and there is the risk of causing further damage. Hence, particularly with newer devices, if you are not confident in your abilities then best to consult an electronics specialist or seek professional assistance from an approved repair centre.
The lesson from this experience is to purchase good quality, branded accessory leads and dispose of any cables where the connector shows signs of wear.
Maintenance of new and legacy systems
@Yellowsbestltd our mission is “Keeping Customers Operational”, by assisting with with the repair of parts for infrastructure systems. These are typically established, long-standing and therefore proven and fit-for-purpose. It makes sense to maintain and extend the life of these systems, as wholesale replacements will be costly and disruptive. This is particularly applicable when the service requirements have not changed, so functionality upgrades are not necessary.
Wewould be keen to hear from you should you have any repairs requirements. Please get in touch to let us know how we can help. By example, there follows a list of a few recent requests we have been able to assist with. We look forward to hearing from you with any feedback you may have.
When providing a spare parts for a Customer’s project requirements, one of the transmission cards to be used was missing its 5-way pluggable terminal block, without which, it is impossible to wire up and install.
Happily we were able to source this from Farnell; this was supplied incredibly speedily – same day dispatch, next day delivery! It’s often the case that little things like this makes big difference in achieving project completion and maintaining operational performance.
@YellowsBestLtd our mission is in “Keeping Customers Operational”. We’re always keen to enhance our range of #business services, increase the #enterprise infrastructure we support and expand our mix of #sustainable solutions we offer for supply and maintenance of new and legacy #technologies and products for our customers.
Please help us understand your management services or solutions requirements, whether you’re implementing new systems or maintaining existing infrastructure networks to serve your operational business needs.
YellowsBest, with our mission of “Keeping Customers Operational” by providing solutions and services to support and enhance infrastructure systems, is celebrating our 7th Anniversary milestone.
Sincere thanks to our loyal Customers and suppliers in making this achievement possible. We look forward to continuing to assist in fulfilling requirements for #business consultancy, #enterprise infrastructure support services, spares and repairs #sustainable solutions for maintenance and the supply of new and legacy #technologies and products for our customers.
The XMP1 product is multi-service access / transmission node equipment capable of PDH data rates of 8Kbps to 34Mbps and SDH STM-1 or STM-4. Originally manufactured by Marconi, the range was taken over in later years by Keymile and Bosch before being discontinued.
The system is still in service, customers include Utilities and Transport organisations, and typically deployed as a terminal multiplexer or as an ADM (Add-Drop-Mux). It can provide point to point or leased line in a corporate network for POTS, data, LAN, IDSN etc.
The building blocks of the system are the central unit which provides control and management, the SDH cards for STM-1 and STM-4 aggregation and the line units which provide uplink in the form of E1, E3 or SHDSL which can be copper or optical. 8 and 16 Slot versions were available as well as an SL (slimline) variant.
Spares and Repairs for continued long-term operation and maintenance
Whereas these products are no longer manufactured, @YellowsBestLtd is able to supply a limited amount of spare parts and/or offer repair services in order to aid customers in keeping their networks operational. There follows a non-exhaustive list of typical parts that can be supplied, we would be very pleased to receive specific requests for items that are needed.
A205HAT00080AAB
05HAT00080AAB
XMP (MK2) POWER SUPPLY 48/60V
AN00059057
62.7026.353.00-A001
PORT HDB3 (2)
AN00098224
62.7040.405.00-A001
MODUL V.11
AN00114784
62.7040.303.00-A001
ETHERNET ADAPTER
AN00118106
62.7006.430.00-A002
POWER SUPPLY 48-60V
A2AN00034165
Cable Clamp
A2AN00086011
CABLE CLAMP PANEL 1 HU
A2AN00086013
PATCH PANEL V.11
A2AN00102460
CCU-CENTRAL UNIT CC WITH QD2
A2AN00102463
SUBRACK XMP1 (16)
A2AN00109256
FRONTPANEL BLUE
A2AN00116240
Connecting Cable 2m
A2AN00214510
Connecting Cable Central Unit Protection
A2AN00214511
Ethernet Cable (5m)
A2AN0022815
DSK MODULAR
A2AN00274356
Input/Output Alarm Cable(2 O/P,3 I/P)
A2AN00276278
Connecting Cable 6m (Port HDB3) coax
A2AN00276281
Connecting Cable 20m (Port HDB2) coax
A2AN0034165
Cable Clamp
A2AN00702802
Mounting element
A205HAN00499AAC
XMP1-SL CROSS CONNECT
XMP1 spares
@YellowsBestLtd our mission is in “Keeping Customers Operational”. We’re always keen to enhance our range of #business services, increase the #enterprise infrastructure we support and expand our mix of #sustainable solutions we offer for supply and maintenance of new and legacy #technologies and products for our customers.
Please help us understand your management services or solutions requirements, whether you’re implementing new systems or maintaining existing infrastructure networks to serve your operational business needs.
Following on from our recent post on our Solar Power System – On Grid Project, the observation has been made that it’s rather inefficient to generate power as DC electricity, and convert it to a higher AC voltage, before converting it back again to DC to suit many consumer applications.
The issue of use of AC or DC is not a new one. Famously, in 1893, Thomas Edison who promoted the generation and use of DC ‘lost’ the battle to George Westinghouse who gained acceptance for the generation of AC at the Chicago World’s Fair, since it was more efficient in long-distance transmission.
This has been the situation for more than a century and still applies with generation at remote power stations and transmission at high AC voltage to feed and satisfy local demand. The 240V (in the UK) AC mains electricity that is delivered to a household is perfectly suitable in this form for domestic high power applications i.e. cooker, washing machine, etc. On the other hand, electricity is used for variety of low-voltage DC devices and gadgets e.g. phones, TVs, computers and so on, contain power adapters converting AC to DC and stepping down to typically 12v or 5v USB. Lighting is traditionally AC, but with advancement in LED technology could be of a lower DC voltage.
The development of locally generated solar energy changes things somewhat. The generation output is low voltage DC. The majority of this generated electricity is utilised locally. Excess energy can be stored in batteries, which are also low voltage DC. This could be used in this form, but in order for a household to be able to supplement locally generated energy, when the sun doesn’t shine (night time / winter), it still has to be wired to receive AC from the grid-based electricity. Also, to facilitate the export of excess energy (an increasingly valuable benefit of domestic solar power generation), the locally generated electricity must be converted to grid-compatible AC, using an inverter.
It should be the case that houses of the future are designed and built with solar panels on the roof. Indeed, it is now the case they are cheaper that slate, and so the materials and labour charges would be negligible costs if part of the build rather than as an add-on. In which case, the building could be designed with 12V DC and 5V USB supplementary to the 240V AC for mains wiring, feeding appliances directly at the type of voltage they require, eliminating power rectifiers and most voltage converters.
This ‘direct supply’ is already demonstrated in our Solar energy off-grid eBike charger project with the generated supply connected to a AA / AAA / C / D / PP3 battery charger using its 12V DC input (bypassing a 240V AC input, which requires internal conversion). The 12V supply also feeds LED lights without voltage conversion.
Similarly, the 5V USB outputs of the solar charger controller can charge iPhones and other gadgets.
‘Highway to Hell’ – EV charging & V2X
We know that Electric Vehicles (EVs) are going to be increasingly in use and will gradually take over from petrol and diesel engines.
And so the ability to charge these at home will be increasingly important and convenient. Some cars are already of a Plug-in Hybrid Electric Vehicle (PHEV) type, meaning that they can be charged from a domestic UK 240V AC supply for local use.
Another key development is the concept of EV batteries being used as supplementary storage for a household, so called ‘Vehicle to Home’ (V2H), ‘Vehicle to Building / Business’ (V2B) or ‘Vehicle to Grid’ (V2G) [collectively V2X indicating bi-directional, as opposed to single direction V1G], charging at low demand and discharging when household usage is greater, or to take advantage of higher export pricing.
The AC supply is needed to be converted to a DC voltage useable by the car batteries, and similarly the car’s electricity needs converting from DC to AC for household export. There are two ways of achieving this, by having a converter in the charger or the car. But if the premises has its own source of accessible DC power, ideally sourced from locally generated solar energy, then this conversion would be unnecessary.
Another issue is that UK 240V AC is limited to 13A supply from standard household sockets (for most domestic use) providing slow charging at 3kW. A dedicated charging point using a UK Type 2 connection is an improvement with direct connection to the mains consumer unit, providing charging at 3.6kWh from a 16V AC supply or 7.4 KW from a 32V AC supply. Faster charging is possible with 11kW from 32A AC supply or faster still with 22kW from 63A AC supply, but these are more expensive, beyond the available power of many households and require a 3-phase supply.
The European Union has specified the Combined Charging System (CCS) standard to permit both AC and DC charging. Much faster and more efficient charging at 100kW and beyond is possible using DC charging, eliminating the conversion in the vehicle. However, this is currently an even more expensive solution and limited to EVs that can accept a compatible DC input. Charging at commercial sites such as motorway service stations offer a variety of standards, including the CCS (Europe), CHAdeMO (Japan), GB/T (China) or Tesla Supercharger (propriety).
This conversion and compatibility issue is not confined to motor vehicles. As highlighted in the Solar energy off-grid eBike charger project, conversion using an inverter is necessary from the 12V DC power generated from the Solar Panel and stored in the battery, to 240V AC used by the required charger, which then converts again into 36V DC. The problem is not just related to type and size of voltage, as the lithium batteries used require special adapters to perform the charging correctly. It would be possible to produce these fed from a specialist DC adapter, but such chargers are more difficult (and expensive) to obtain, given that the domestic supplies are generally not available in this form and so consequently the demand for these products is not yet there.
‘Thunderstruck’ – Solar powered cooling (mini project)
Given the current heat-wave and the likely-hood of more temperature extremes as a result of climate change, coupled with cost-of-energy crises and possible supply shortages, it seemed appropriate to build another solar power project, this time focusing on powering a cooling fan with energy from the sun.
The concept is relatively straight-forward: using solar energy to assist with cooling. When sitting out and the sun is shining and the temperature is too hot, the sensible thing to do is shelter under some shade. But when there is little-to-no breeze, even in the shade it gets too hot to bare. In which case, a simple fan can help. The one selected was an old, cheap USB model, which provides a limited amount of cooling, but doesn’t require much energy to operate. Also chosen was a small, also old, and low-cost 6V solar panel, which provides just enough energy to power a USB device using a suitable conversion lead.
But this isn’t particularly robust since a slight drop in sunshine can stop the set-up working. Hence this has been additionally paired with a battery power bank, which can simultaneously be charged with the solar energy whilst also powering the fan.
Naturally, the battery pack can be charged separately – ideally powered by locally generated and stored solar energy!
‘For those about to Rock’ – the Electric future
Hopefully this has been food for thought into the exciting fast developing world of solar power generation and the electric future. Please get in touch if you have questions, comments or ideas to share.
@YellowsBestLtd our mission is in “Keeping Customers Operational”. We’re always keen to enhance our range of #business services, increase the #enterprise infrastructure we support and expand our mix of #sustainable solutions we offer for supply and maintenance of new and legacy #technologies and products for our customers.
Please help us understand your management services or solutions requirements, whether you’re implementing new systems or maintaining existing infrastructure networks to serve your operational business needs.
Obtaining low-cost renewable solar energy has always had much appeal, but historically the investment costs has been rather off-putting, especially in the U.K. where it is perceived that the climate doesn’t provide a reliable enough amount of sunshine.
However, in recent years a number of things have changed this evaluation. Performance improvements in solar panels and associated power inverters have resulted gains in energy creation, coupled with the availability of modern battery arrays substantial enough to store the energy produced for later reuse. At the same time, shocks to world fuel prices have results in a rapid shorting of the ‘payback period’; once it was considered that a typical household solar installation would take in the order of 25 years to recoup the investments costs. This has tumbled to around an estimated 8 years based on calculations made last year, and taking into account the recent price increases for domestic electricity supply, the period could be approaching 4 years with further shortening likely as energy prices continue to rise. The recent removal of VAT by the UK government on the implementation of solar energy systems is an added boost.
One additional further benefit that has recently arisen is the introduction by some power utility companies, such as Octopus Energy, of ‘agile’ export tariffs, which pay increased amounts at peak demand times. This can be taken advantage of by the use of smart meters, supplying surplus generated or stored energy to the grid at the best times to maximise revenue, offsetting the purchase of electricity from the grid at other times.
Given that the future is anticipated to require increasing use of electricity to provide power for EV cars and hybrid vehicles, generating your own electricity makes increasing sense.
Overview of our implemented system
Given the now obvious benefits of a solar energy, we have acted accordingly and implemented a system, which has the following component parts:
13x 385W JA Solar Monocrystalline Panels with PERC technology, limited by the available roof space, but sufficient for energy needs.
Alumero Mounting accessories & Tigo Optimisers to enhance performance when part of the solar array is shaded.
Luxpower Hybrid Auto Inverter, 16A single phase, to convert the generated 12V DC electricity to 240V AC for household consumption or export.
4.8 kW Aoboet Uhome battery storage array to store excess energy for later use.
AC and DC isolators to connect the component system parts.
Generation meter to measure energy production.
Wifi Monitoring portal for displaying instantaneous and historical performance.
The calculated annual yield for this system is 3,679kWh, which should be enough to fulfil the household’s electricity needs, estimated at 3,207kWh based on previous usage.
Solar Panels – the ‘heart’
Key to the collection of energy from the sun are naturally the solar panels. These vary in size, and technology is improving continuously, so the latest available are more efficient than previous generations.
Those selected for this project were 13 x 385W JA Solar Monocrystalline Panels with latest PERC (Passivated Emitter and Rear Cell) technology. Monocrystalline are more expensive but more efficient, with a longer lifespan than other types available. PERC technology improves light capture near the rear surface, optimising electrons flow and thereby achieving higher efficiencies.
The amount produced by a solar array naturally depends on sunlight hours and will be much lower with poor weather or as daylight reduces, whilst household electricity demand also varies during the day.
The ultimate aim of using solar power is to reduce as far as practically possible the need to source energy from the grid. Consequently, a larger array of modules than those just to meet the typical usage amount is needed to ensure adequate production whatever the weather, with the excess being stored or exported.
Alumero mounting kits were used for fixing the solar panels to the property roof, together with Tigo optimisers which maximise the generation from each panel. Without such optimisation, the power output from all solar modules can be reduced when some of the array is in shade.
DC isolators connect two ‘strings’ of series connected panels to the Hybrid Inverter.
Hybrid Inverter – ‘the brains’
In order for the system to be truly useful, power conversion and energy management functions are needed, to ensure a seamless and uninterrupted supply of electricity from the available sources i.e. an appropriate mix of the local generation, storage and grid supply. Chosen for this installation was a Lux Hybrid Automated 16 Amp single phase inverter.
The Hybrid Inverter ensures that when solar energy is available i.e. during daylight hours, this is firstly routed to provide for domestic consumption, and then used to charge the battery storage (as required, if not full). Any additional energy is exported to the external grid. When there is not enough energy generation from the solar array, the hybrid inverter routes the energy storage to the household, and when this is depleted, electricity is imported from the grid in the usual way. Critically, where to source electricity from is completely seamless such that the domestic consumption is never interrupted and the household is unaware of these ‘decisions’ being made.
It’s the inverter’s job to take the DC electricity produced by the solar panels and turn it into 240V AC electricity for household use. It’s a sad fact that many domestic appliances then take this 240V AC and convert it back to DC and lower voltages like 12V and 5V; this double conversion adding theoretical inefficiencies. But this is simpler to implement than rewiring the entire building and trying to then integrate with power to and from the grid.
AC Isolators connect the Inverter’s output to the household electricity supply.
Batteries – ‘the memory’
Quite literally, ‘saving for a rainy day’ is the function of the batteries, which add to the capability and capacity of solar power generation. They are effectively ‘optional’ since the system can be run without them. But since there is a huge natural variation between maximum sunlight and night-time, it makes sense to capture excess energy at peak times, and use this when sunlight is not available or sufficient.
Chosen for this project were 2x Aoboet Uhome-LFP 2400 providing 4.8kW of storage capacity.
At the beginning of a day, the batteries are naturally somewhat depleted, and therefore excess solar energy is initially used to charge them. Once full, they remain ‘on standby’ until later when generation is unable to fulfil the immediate electricity needs, in which case they start discharging their stored energy. Ideally, they will not become completely depleted over the course of the day and night, so that energy is not needed to be imported from the grid.
Grid – import / export
Electricity from the grid is the “insurance” for times when the solar energy is not able to fulfil demand. Naturally, this is likely to be due to a lack of winter daylight hours and/or poor weather, which of course has to be paid for.
But at other times, there will be an excess of energy that can be exported to earn back some of these costs. A Generation Meter as part of the solar energy system enables this export of electricity.
The bi-directional energy flow is measured with a ‘smart’ meter using a suitable import / export tariff from the Utility company, such as the Octopus with their Agile tariff, and displayed on an associated WiFi monitor.
As to be expected, the amount paid by the Utility for kWh export is considerably less than that charged for import, so it’s worth making best use of the generated and stored energy as much as possible, like running appliances when the sun shines!
An EPS (Emergency Power Supply) socket was additionally included in this project. Though optional, it was chosen for providing ‘backup power’ from the solar energy system in the event of a power outage from the grid supply. It is standard practice in such an event to shut off the export to the grid from solar energy systems to avoid difficulties whilst restoration work is in progress. But during such a period, the household can make use of the generated and stored local energy, for a limited time and restricted to a maximum of 13A. Avoiding excessive consumption, it should be possible to maintain a local supply for 12 hours, assuming a fully charged battery array.
To complete the project to become an ‘energy generator’ (as well as satisfying own consumption needs), an MCS (Microgeneration Certificate Scheme) certificate is issued, together with receiving acceptance documentation from the DNO (District Network Operative). This then allows the establishment of the export tariff with the Utility provider so that payments for excess energy exported will be made.
Operating performance
A WiFi Portal provides the householder with an overview of the current operation of the solar energy system, displaying instantaneous status and historical energy performance for tracking generation yield and import / energy export.
Initially, it can be reported that average energy yield is around 0.86kWh, ranging between a typical peak of 2-4kW during the day and zero at night, compared with average consumption of approximately 0.35kWh, with the excess charging the batteries in the morning and exporting to the grid during the rest of the day. During the night, the consumption is met from the battery storage, with the batteries depleted to around 11% by the next day. It is noted that even during relatively cloudy days, at least around 10% of the 5kWh maximum power is generated, enough to at least meet the immediate consumption needs and even provide some battery replenishment.
A complete picture of the operating performance of the solar energy system will be known after a full year, taking into account the peak of summer and the shortest winter daylight period. Rising costs of electricity will also impact on the longer-term cost savings anticipated.
Conclusions
Hopefully this ‘project description’ is of interest and perhaps of use to anyone contemplating installing a Solar Energy system at their home or office premises. Please feel free to get in touch if you would like us to provide consultancy advice (on a no-obligation FOC basis) leading to a quotation for establishing your own system, or just to gain an in-depth appraisal and more information from our first-hand experience of implementing a Solar Energy system.
Our summary of conclusions at this stage having now implemented a system are:
Solar energy collection has developed rapidly in recent years, particularly now that home energy storage is practical enough to capture excess energy during peak daylight and release it for use during the night or whenever demand exceeds generation.
Although such systems are still a significant investment, given the recent escalation in energy costs, the ‘break-even’ point has reduced dramactically and the trend is for energy costs to continue to rise thereby making the payback period increasingly shorter.
An attractive feature is the notion of being paid to supply energy to the grid, though it should be noted that currently at best this is 7.5p per kWh, so unlikely to be a significant revenue source. But it does mean that energy bills over the longer term will be vanishingly small.
The contribution to the nation’s renewable energy mix helps in a small way to aid the drive to reduced carbon emissions and tackle climate change.
Naturally, a suitable oriented roof or land space for solar panel installation is required, as well as a location for housing the inverter and batteries (loft space is ideal). Plus, it should be noted that a PV cable needs to be installed (most likely running down the outside wall of the building) to link the inverter to the consumer unit.
Should power cuts from the grid occur in the future, the solar energy system is capable (thanks to the EPS socket) of providing power for a limited period to maintain household electricity use.
With the increasing use of electric cars (all new will need to be at least hybrid by 2030), being able to source local renewable energy will make increasing sense.
@YellowsBestLtd our mission is in “Keeping Customers Operational”. We’re always keen to enhance our range of #business services, increase the #enterprise infrastructure we support and expand our mix of #sustainable solutions we offer for supply and maintenance of new and legacy #technologies and products for our customers.
Please help us understand what would be of interest to you by getting in touch to discuss your management services or solutions requirements, whether you’re implementing new systems or maintaining existing infrastructure networks to serve your operational business needs. We look forward to hearing from you.
There may be more challenging times ahead, but this hopefully is a good opportunity to relax and refresh with family and friends. Best wishes to all our Customers and Suppliers, we hope to be in contact again with you soon.
From the beginning of April 2020, all UK VAT-registered businesses will need to keep digital records of all transactions, and then submit VAT returns electronic using compatible software.
Whereas many businesses have already started using Making Tax Digital (MTD), the new deadline means that all businesses of any size that are VAT registered will need to comply.
Signing Up to MTD by the next VAT period due
The new electronic service replaces the ‘manual’ VAT return for businesses on their next submission after the 1st April start date, which remains at the same quarterly interval. So (for example) if the business’s current VAT period is February to April, then this can be completed in the usual way when due in May. But the following VAT period of May to July will require a digital submission in August (and thereafter). Signing up to MTD needs to be made at least 7 days before the date the first MTD return is due. It’s important however not to sign up less than 5 days after the last non-MTD return, to avoid duplication of payments.
Signing up is accomplished via the MTD GOV.UK website, requiring a Government Gateway ID with business and VAT registration information.
Obtaining and using compatible software
Various providers of accounting software are available to both record digital transactions and make the electronic VAT submissions. This also includes using spreadsheets, though in that case bridging software will be needed to make the submission.
A top tip for NatWest Bank business customers is that they will provide the MTB compliant accounting software FreeAgent at no cost.
Assisting with your business requirements
@YellowsBestLtd would be interested to receive feedback on your transition to MTD and any other business transformation challenges you are facing. If appropriate, there may be areas of your business development or operations that we can support with consultancy services e.g. sales and marketing assistance. Please get in touch to discuss how we can be of help.